P. 375


                                    Indexes Technical Data Hoses & Fittings Fittings & Accessories Blow Guns & Accessories Hydraulic QD Pneumatic QDZSi-Foster Engineering Catalog – 375 –Quick Coupling InstallationBe Safe When Installing Quick CouplingsInstallation Of Reusable Hose CouplingsTrim the end of the hose as square as possible.Mark the point of full hose insertion depth with a piece of tape.Add a bit of lubricant to the reusable hose barb before inserting into theferrule.Tighten reusable hose barb into ferrule ensuring hose stays completely inserted.Verify tape line is correct for full insertion.Turn reusable hose barb into ferruleensuring hose stays completely inserted.Completed connection, Use marker applied in step [3] to ensure hose is completely inserted.Insert Hose completely into ferrule and 1 2 make note of how deep the hose goes.3 45 67 8
                                