Quick-Clip & Cush-A-Grip





            Quick-Clip

            Quick-Clip’s unique one-piece composite                                                    Size           Introduction
            polyamide alloy design combines strength with
            light weight. It will overcome the problems of
            using cable ties for piping, electrical, optical and
            network cabling.                                                                                          Channel

                                      3
               • •   Quick-Clip locates easily on  ⁄8" rod
               • •   No breaks in insulation material
                                                                 Standard  Metric
               • •   Fast and easy installation, saves time and   Copper Copper       Copper Tube
                 money                                   Part No.                 3            1         Condensate   Channel Nuts &   Hardware
                                                                                                           Drain
               • •  Single handed installation                    (no insulation)  with  ⁄8" (10mm)  with  ⁄2" (13mm)
                                                                                              Insulation
                                                                                 Insulation
               • •   Manufactured from a composite        QC12     3 ⁄4"   -        -            -           -
                 polyamide, tested from -40°F to + 275°F,   QC14   7 ⁄8"  22mm      -            -          yes
                 (-40°C to +135°C) makes it ideal for     QC16     1"      -      1 ⁄4" tube     -           -        General   Fittings
                 network cables                                    1              3
                                                          QC18     1 ⁄8"  28mm     ⁄8" tube      -           -
               • •   Studding panel inserts.              QC20     1 ⁄4"   -      1 ⁄2" tube   1 ⁄4" tube    -
                                                                   1
                                                          QC22     1 ⁄8"   -      5 ⁄8" tube   3 ⁄8" tube   yes
                                                                   3
                                                          QC24     1 ⁄2"   -      7 ⁄8" tube   5 ⁄8" tube    -        Brackets
                                                                   1
                                                                   5
                                                                                  1
                                                          QC26     1 ⁄8"  42mm    1 ⁄8" tube   3 ⁄4" tube   yes
                                                          QC32     2"      -        -          7 ⁄8" tube    -
                                                          QC34     2 ⁄8"  54mm    1 ⁄8" tube   1 ⁄8" tube   yes
                                                                   1
                                                                                               1
                                                                                  3
            Slide onto threaded rod, twist to engage.   Inside diameter: Certain clips have two or more positions to accommodate both metric   Beam   Clamps
            Insert pipe and clip to lock.               and standard sizes
                                                                                       7
                                                                                      1 ⁄16"
                                                                                 D    37mm
            Cush-A-Grip                                                     C                                         Pipe & Conduit   Supports
            FEATURES:
                                                                          B                                    Hex Bolt
               • •   Ten sizes of tube, five sizes of pipe               A                            Size
               • •  Diameters from .25" to 1.31"                                                      Range
            ADVANTAGES:                                                                                               Electrical   Fittings
               • •  Reduces inventory SKU’s                                               V-Pad       "V" Pad
               • •   Simplifies take-offs and requirements on
                 projects using both tube and pipe sizes
               • •  Easy installation, non-conducting    Part           O.D.          Pipe      Metric    Diameters   Spring   Steel
               • •  Permissible outdoors                  No.     1  Tube Sizes  1    Sizes     Sizes       (in)
                                                                        3
                                                                                       1
               • •  Temp. range: -40˚F to +380˚F (-40°C to 193°C)  CG-10  5 ⁄4"  3 ⁄8"  7 ⁄2"  3  ⁄4" 1  6mm – 14mm  0.25 – 0.54
               • •   No galvanic reaction, Will not rust   CG-20  ⁄8"    ⁄4"    ⁄8"   ⁄8" –  ⁄2"  15mm – 22mm  0.62 – 0.87
                                                                               1
                                                         CG-30    7 ⁄8"  1"   1- ⁄8"   3 ⁄4"  22mm – 28mm  0.87 – 1.12
            BENEFITS:                                    CG-40    1"    1- ⁄8"  1- ⁄4"  3 ⁄4" – 1"  26mm – 32mm  1.00 – 1.31  Concrete   Inserts
                                                                         1
                                                                                1
               • •   Lowers overall inventory costs             Nominal           Dimensions             Hex Head
               • •   Works with screw or nut driver      Part    Pipe                                    Cap Screw
               • •   Resists vibration                   No.     Size    "A"      "B"     "C"     "D"    & Lock Nut
               • •   Use in place of steel clamps with steel tube        15       3       3       3                   Rooftop   Supports
                                                                                                               1
               • •   Multi-environmental                 CG-10    1 ⁄4"  1- ⁄16"   1- ⁄8"  ⁄8"    ⁄16"   1 ⁄4"-20 x 1- ⁄2"
                                                                        (49mm)   (35mm)  (10mm)  (5mm)
               • •  Covers a wide range of applications and      3       2- ⁄8"   1- ⁄8"  7 ⁄16"  1 ⁄4"   1
                                                                                  5
                                                                          3
                 maintains thermal barrier               CG-20    ⁄8"   (60mm)   (41mm)  (11mm)  (6mm)    ⁄4"-20 x 2"
               • •  For use on copper tube                       1 ⁄2"  2- ⁄16"   1- ⁄16"  7 ⁄16"  5 ⁄16"   1 ⁄4"-20 x 2"
                                                                          9
                                                                                  13
               • •  Use in place of stainless, aluminum, PVC or hot   CG-30  (65mm)  (46mm)  (11mm)  (8mm)            Technical   Data
                                                                                  15
                                                                         11
                 dipped galvanized clamps                CG-40    3 ⁄4"  2- ⁄16"   1- ⁄16"  7 ⁄16"  5 ⁄16"  1 ⁄4"-20 x 2"
                                                                        (68mm)   (49mm)  (11mm)   (8mm)
            www.zsi-foster.com                                                                              – 207 –